LED High Bay Selection Guide: Wattage, IP Rating and Controls for Warehouses

A warehouse lighting upgrade looks simple on a spreadsheet: replace each old lamp with a lower-wattage LED high bay and read the energy saving off the difference. In practice, the projects that disappoint are the ones that started from wattage. Mounting height, racking layout, optics, ambient temperature and control zoning determine whether a space ends up evenly lit or full of bright pools and dark aisles.

This guide sets out the sequence our engineers use when sizing industrial luminaires for factories, logistics centres and sports halls, and the numbers that should appear in a tender submittal.

1. Start with mounting height, not wattage

Mounting height sets the beam angle, the spacing and the lumen package. Below about 6 m, lower-output fixtures with wider optics give better uniformity and less glare for pickers looking up at a rack. From 6 to 10 m, a medium distribution with a 90°–120° beam is typical. Above 10 m, narrower optics and higher lumen packages are needed to push usable light to the floor without washing out the ceiling.

Racking changes everything. In a narrow-aisle warehouse, a round symmetric beam wastes light on top of the racks; an aisle-optic distribution puts it down the aisle where the picker works. Always model the racking, not just an empty box, in the lighting calculation.

2. Wattage and lumen output: a practical range

Work backwards from the target illuminance at the working plane. Storage aisles commonly sit around 150–200 lux, picking and packing areas around 300 lux, and inspection or assembly zones 500 lux or more. Divide the required lux by the utilisation factor and maintenance factor, then select the lumen package. Wattage follows from efficacy, not the other way round.

As a rough orientation for a 8–10 m ceiling, 100–150 W high bays at sensible spacing cover general storage, while 200–240 W units suit high-ceiling or high-lux zones. FEIDI’s industrial lighting range spans UFO and high bay fixtures from 50 to 240 W, which lets one family cover both a low mezzanine and a tall main hall. Treat these as orientation only — a DIALux calculation with the real IES file is the specification of record.

3. Optics and uniformity, not just peak lux

A single headline lux figure hides a bad layout. Ask for the average, the minimum and the uniformity ratio (min/average) across the working plane. Aisles with bright circles and dark gaps force workers to adapt constantly and create forklift shadow zones; a slightly lower but even average is safer and more comfortable.

Glare matters as much in a warehouse as in an office, because operators regularly look up to read rack labels. Recessed optics, diffusers and careful mounting offsets reduce direct view of the LED array. Where the ceiling is exposed, specify a shield or a deep reflector rather than a bare flat emitter.

4. IP rating, ambient temperature and thermal design

IP65 is the working default for dusty or wash-down industrial areas; IP66 adds protection where hosing or heavy moisture is present. Food processing, cold storage and coastal facilities should also ask about the housing finish, gasket material and driver sealing — condensation inside the driver compartment is a more common failure than water on the lens.

Thermal design is the real lifetime variable. LED lumen depreciation accelerates with junction temperature, so a high bay mounted near a hot roof or above a furnace needs a larger heat sink or a lower drive current than the same fixture in a temperate aisle. Ask for the rated ambient temperature (Ta), the L70 lifetime at that temperature, and the LM-80 or TM-21 basis for the claim. A fixture rated L70 50,000 h at Ta 25 °C is not rated 50,000 h at Ta 50 °C.

5. Controls: 0-10V dimming, sensing and zoning

Controls often deliver a larger saving than the lamp swap itself. 0-10V dimming is the industrial workhorse: simple, reliable and compatible with most zone controllers. Occupancy or daylight sensors suit intermittent areas such as loading bays and storage aisles; group luminaires by logical zone (aisle, dock, mezzanine) so one sensor does not black out an entire hall.

Specify the dimming curve and minimum level in the submittal, and confirm the sensor’s mounting height rating — a sensor specified for 4 m will not reliably cover a 12 m aisle. Where a building management system is present, agree the interface (0-10V, DALI or a relay contact) before ordering drivers. Our guide to control protocols covers the trade-offs in more detail.

6. Retrofit maths: what a swap actually saves

Build the comparison from measured input watts, not nameplate watts, and include ballast losses on the existing installation. Then add operating hours, the maintenance labour avoided over the fixture lifetime, and any control savings. A realistic model separates three benefits: the LED efficacy gain, the removal of ballast and lamp replacement labour, and the dimming or occupancy reduction.

Do not double-count. If the new layout is dimmed for half the operating hours, the energy figure already reflects that; do not add it again as a separate line. Also budget for disposal of the old lamps and for any rewiring needed to bring the control pairs to each luminaire.

7. Five mistakes that shorten high bay life

  • Selecting on wattage alone — ignores mounting height, reflectance and racking geometry.
  • Ignoring ambient temperature at the mounting point — the hottest air in a building sits at the roof.
  • Using symmetric optics in narrow aisles — lights the rack tops instead of the picking face.
  • Skipping the uniformity check — a good average lux can hide dangerous dark gaps.
  • Leaving sensor height and zoning undefined — commissioning failures are expensive to revisit at 12 m.

Quick spec checklist

ParameterTypical warehouse targetWhat to request
Mounting heightRecord actual height and racking geometryLayout drawing with rack heights
Illuminance150–200 lux storage, 300 lux picking, 500 lux inspectionDIALux calculation with min/avg uniformity
Lumen packageOrient from 50–240 W families, size by luxIES / LDT file and efficacy figure
OpticsAisle distribution for racked areas, wide for open hallsBeam data and polar diagram
Ingress / thermalIP65 standard, IP66 wash-down, Ta statedIP report, Ta rating, L70 / TM-21 basis
Controls0-10V zoning, sensing in intermittent areasDimming curve, sensor height rating, BMS interface
DocumentationSubmittal pack before orderDatasheet, IES files, wiring diagram, warranty terms

Frequently Asked Questions

What wattage high bay do I need for an 8 m warehouse?

For general storage at 8-10 m, 100-150 W LED high bays at sensible spacing are a common starting point, with 200-240 W for high-lux or taller zones. Size the final choice from a lux calculation using the real IES file, because racking and reflectance change the answer substantially.

Is IP65 enough for a warehouse?

IP65 covers dusty and most wash-down industrial areas. Choose IP66 where hosing, heavy moisture or frequent cleaning is expected, and ask separately about gasket material and driver sealing in cold storage or coastal sites.

Why do some LED high bays fail early in hot buildings?

Junction temperature drives lumen depreciation and driver life. The hottest air sits at roof level, so a fixture rated at Ta 25 C may be well outside its rating at Ta 50 C. Ask for the rated ambient temperature and the L70 or TM-21 basis at that temperature.

Should I use 0-10V or DALI in a warehouse?

0-10V is usually the pragmatic choice for large grouped zones: simple, robust and widely supported. DALI makes sense where individual addressing, scene recall or status feedback is needed, such as mixed-use halls or automated logistics areas.

How much can a high bay retrofit actually save?

Model three separate benefits: the LED efficacy gain, avoided lamp and ballast replacement labour, and control savings from dimming or occupancy sensing. Use measured input watts including ballast losses, and avoid adding control savings twice.

Related reading and product ranges

More FEIDI buying guides

Planning a warehouse or factory upgrade? Review the FEIDI industrial lighting range (UFO and high bay, 50–240 W, IP65/IP66), or send us your hall dimensions and racking layout for a lighting calculation and datasheet pack.

Leave a Comment